kic2000炉温测试仪从炉子里出来读不出数据怎么办?
发布网友
发布时间:2022-04-19 21:23
我来回答
共4个回答
热心网友
时间:2023-07-11 06:06
通常是仪器过热自动保护后怎样进行复位?
退出KIC2000软件
1,找到KIC Profiler 2000\Log\kic2000usersettings.kiccfg ,用记事本方式打开
2,把文件中的ViewHostDialog=0改为=1,然后保存并退出。
再次启动KIC2000软件你就可以看到KICHost界面了。
Can try these steps, remark to using English Language
Recommend is use 9V ALKALINE Battery
1.Make sure the SlinKIC2000 software is close.
2.Under the root directory on your hard drive, under the folder the KIC Profiler 2000 you will find a folder called "Log".(Using Windows Explorer, open the X:\KIC Profiler 2000\Log\kic2000usersettings.kiccfg file)
3.Under the Log folder there is a file called "KIC2000UserSettings.KICCFG"
4.Open this file using Note or WordPad text editor.
5.With file opened under the text editor, find the line: ( " ViewHostDialog=0", Set this line to =1, Save changes to the file. )
6.Restart the SlimKIC2000 software and you motice that a second application will open, the KIC Host. ( On the Windows Taskbar, click on the "KIC Host" tab)
7.Direct connection to SlimKIC2000, restart SlimKIC2000 Unit.
8.Select "Configure SlimKIC" .
9.Another Window will open. Select "Write SlimKIC Setuop" . You should see dialog appear in that window which says " Write SlimKIC Successful".
由深圳市时汉电子为你专业服务,如有不明白的地方。CALL: 138 0270 8085 唐/R
热心网友
时间:2023-07-11 06:07
曲线往下跑是测温线正负极接反了
报“必须超过启动点130以上。”你的温度太低。仪器认为你没有完成一次炉温测试,所以不能下载。如有需要可以电话186 203 77855,换几条新的测温线就行了
热心网友
时间:2023-07-11 06:07
1,没电了 2,通讯线有问题 3,开机与记录有误,没采集到数据 4,仪器主板坏了。追问:
kic2000炉温测试仪在完成曲线测量后,数据不能下载到电脑上,且曲线往下跑,
且报什么“必须超过启动点130以上。。。。”什么的
用其他PCBA测量可以,请教大家是怎么回事啊
热心网友
时间:2023-07-11 06:08
隔热盒垃圾!芯片受到高温了。